Is there a way for us to see the haunch load at girder tenth points that PG Super is calculating? We need to see it to verify that the program is calculating it correctly for our calculation packages.

In addition, does the option "Natural excess camber is zero" mean that that haunch load is a straight uniform load (i.e. that the haunch depth for load purposes is equal to the A dimension that we set at bearing centerlines)?

Thanks!

Rick Brice
PG Super - Haunch Load

Haunch load details are listed in the Loading Details section of the Details report.

Here is information about the haunch dead load settings.
https://www.wsdot.wa.gov/eesc/bridge/software/Documentation/PGSuper/4.1/...