Replacement Girder Design

1 post / 0 new
jbauman
Replacement Girder Design
AttachmentSize
Binary Data Model File845.04 KB

I am designing a replacement girder for an existing span. When running girder designer, the Design Outcome pop-up summary states that I have 48 total prestressing strands, of which 38 are straight strands and 10 are adjustable straight strands. However, when opening the summary report, it is stated that while I have 48 total prestressing strands, only 2 are adjustable straight strands. I would like to get clarification on this discrepancy. Please clarify. I am uploading my model file. Thank you.