PG Splice - Integral Closure Joint

3 posts / 0 new
Last post
struct23
PG Splice - Integral Closure Joint

Whenever I try changing the closure joint type to Integral Closure Joint, the program automatically resets it to Continuous Closure Joint. I am using a physical model of the pier. Is there a setting or option I need to utilize in order to get the program to maintain the Integral Closure Joint option? Thanks.

Rick Brice
PG Splice - Integral Closure Joint

There is a bug that prevents changing boundary conditions from Continuous Closure Joint to Integral Closure Joint. We will get that fixed up ASAP.

In the meantime, there is a work around. Change the boundary conditions from Continuous Closure Joint to Continuous Segment. Then change from Continuous Segment to Integral Closure Joint.

struct23
Thanks for the reply. This

Thanks for the reply. This worked.

Log in or register to post comments