Hi Rick,

Does PGSuper allow to input multiple load cases and automatically analyze for the worst condition?

Thanks,
Yan Liu

Rick Brice
PGSuper Load Cases

PGSuper has load cases (DC, DW, etc) and limit states (Service I, Service III, Strength I, etc) as prescribed by the LRFD. There is not a way to create your own load cases or limit states.

For live load, you can use multiple loading conditions and PGSuper will envelope the results and use the worst case. Select Loading > Live Loads. Check the live loads to be included in the Design, Fatigue, and Permit limit states.